Summary for Test 2019-10-05-4-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114 |
---|---|
DIST-CO-RTE-PM | 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2 |
Award Date | 04/18/2019 |
Closeout Date | 06/28/2022 |
Work Description | REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/17/2019) |
Sample Information
Sample Taken Date | 10/05/2019 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/07/2019 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | RMA | Last name of sampler or witnessed by | Technician |
Title of sampler | QC Tester | Telephone number of sampler | |
Laboratory sample identification | 999-91 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Short Load Concrete | Transportation Laboratory (TL) Number | 91 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | 60WB at 3700 linear ft |
Material Information
Material Type | Concrete | The concrete mix design number | CMAX 30 RAM |
---|---|---|---|
The truck number from where the sample was collected | na | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | JMECI |
A detailed description of where the material sample was collected | set 3 | Where the material sample would have been placed if not sampled | 60WB at 3700 linear ft |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-10-05-4
DIME Test ID: 2019-10-05-4-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-10-15
Test Results
Unit system used?: US Units
Number of specimens: 6
Test performed: With no density determined
Input Type: Measured
Tester's full name: FO
Date of test: 10/12/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Average diameter of cylinder 3: 6.02 in
Average diameter of cylinder 4: 6.01 in
Average diameter of cylinder 5: 6.00 in
Average diameter of cylinder 6: 6.01 in
Maximum load on cylinder 1: 23220 lb
Maximum load on cylinder 2: 24180 lb
Maximum load on cylinder 3: 26340 lb
Maximum load on cylinder 4: 24990 lb
Maximum load on cylinder 5: 23890 lb
Maximum load on cylinder 6: 24950 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Type of fracture pattern of cylinder 4: 3
Type of fracture pattern of cylinder 5: 2
Type of fracture pattern of cylinder 6: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Correction factor for cylinder 4: 1
Correction factor for cylinder 5: 1
Correction factor for cylinder 6: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Cross sectional area of cylinder 3: 28.46 in^2
Cross sectional area of cylinder 4: 28.37 in^2
Cross sectional area of cylinder 5: 28.27 in^2
Cross sectional area of cylinder 6: 28.37 in^2
Compressive strength of cylinder 1: 818.5 psi
Compressive strength of cylinder 2: 852.3 psi
Compressive strength of cylinder 3: 925.5 psi
Compressive strength of cylinder 4: 880.9 psi
Compressive strength of cylinder 5: 845.1 psi
Compressive strength of cylinder 6: 879.5 psi
Compressive strength (to nearest 10 psi): 870 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/15/2019 ✔