Summary for Test 2019-10-05-3-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 213746
DEA: 080Q75U4
EFIS: 0817000114
DIST-CO-RTE-PM08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Award Date04/18/2019
Closeout Date06/28/2022
Work DescriptionREPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location DescriptionNot set
QA Service Level1 (Verified on 06/17/2019)

Sample Information

Sample Taken Date10/05/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2019
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byRMA Last name of sampler or witnessed byTechnician
Title of samplerQC Tester Telephone number of sampler
Laboratory sample identification999-90 Linked DIME Sample ID
The fabricator/manufacturer/facility nameShort Load Concrete Transportation Laboratory (TL) Number90
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name60WB at 1805 linear ft

Material Information

Material TypeConcrete The concrete mix design numberCMAX 30 RAM
The truck number from where the sample was collectedna The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleJMECI
A detailed description of where the material sample was collectedset 2 Where the material sample would have been placed if not sampled60WB at 1805 linear ft
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-10-05-3
DIME Test ID: 2019-10-05-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-10-15

Test Results


Unit system used?: US Units
Number of specimens: 6
Test performed: With no density determined
Input Type: Measured
Tester's full name: FO
Date of test: 10/12/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Average diameter of cylinder 3: 6.00 in
Average diameter of cylinder 4: 6.01 in
Average diameter of cylinder 5: 6.00 in
Average diameter of cylinder 6: 6.02 in
Maximum load on cylinder 1: 75590 lb
Maximum load on cylinder 2: 73080 lb
Maximum load on cylinder 3: 72610 lb
Maximum load on cylinder 4: 76530 lb
Maximum load on cylinder 5: 77070 lb
Maximum load on cylinder 6: 72950 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 3
Type of fracture pattern of cylinder 4: 2
Type of fracture pattern of cylinder 5: 2
Type of fracture pattern of cylinder 6: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Correction factor for cylinder 4: 1
Correction factor for cylinder 5: 1
Correction factor for cylinder 6: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Cross sectional area of cylinder 4: 28.37 in^2
Cross sectional area of cylinder 5: 28.27 in^2
Cross sectional area of cylinder 6: 28.46 in^2
Compressive strength of cylinder 1: 2673.9 psi
Compressive strength of cylinder 2: 2585.1 psi
Compressive strength of cylinder 3: 2568.4 psi
Compressive strength of cylinder 4: 2697.6 psi
Compressive strength of cylinder 5: 2726.2 psi
Compressive strength of cylinder 6: 2563.2 psi
Compressive strength (to nearest 10 psi): 2640 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/15/2019