Summary for Test 2019-09-05-30-1

Test performed: ASTM D92-12b

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/05/2019 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2019
Sample typeQuality Control A brief description of the sample3/4 inch RHMA-G SP WMA
The quantity of what the sample constitutes1 From where was the sample collectedSource
First name of sampler or witnessed byMarina Last name of sampler or witnessed byKamel
Title of sampler Telephone number of sampler707-259-5708
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Lake Herman Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Modifier Asphalt Modifier TypeUnknown
Asphalt Modifier Mix NumberNot set

Test Details

DIME Sample ID: 2019-09-05-30
DIME Test ID: 2019-09-05-30-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Test Release Date: 2020-12-10

Test Results


Unit system used?: SI Units
Ambient Barometric Pressure unit?: mm Hg
Input Type: Calculated
Tester's full name: Lake Herman Lab
Date of test: 09/05/2019
Corrected Flash Point: 216 C
General comments (publicly viewable) (Max 1000 characters): Asphalt Modifier - ASTM D92

Test was verified on 12/10/2020