Summary for Test 2019-09-19-10-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/19/2019 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/20/2019
Sample typeVerification A brief description of the sample3/4" Aggregate for a RHMA-G JMF
The quantity of what the sample constitutesJMF Prequalification Program From where was the sample collectedManufacturer
First name of sampler or witnessed byRahshaun Last name of sampler or witnessed bySpears
Title of samplerTransportation Engineer Telephone number of sampler(916) 227-0384
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002::LAKE HERMAN QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedFrom the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-09-19-10
DIME Test ID: 2019-09-19-10-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-09-26

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: BN/PM/JH
Date of test: 09/26/2019
Cumulative Mass RetainedCumulative Percent Passing
5507.9 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
1003.5 grams81.8 %
2056.4 grams62.7 %
0 grams100 %
4200.5 grams23.7 %
321.7 grams12.1 %
406.9 grams9.1 %
452.6 grams7.4 %
510.3 grams5.4 %
567.1 grams3.3 %
589.1 grams2.54 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/26/2019