Summary for Test 2019-09-04-7-2
Test performed: ASTM C109-16aProject Information
Project Identifiers | Project ID: 214029 DEA: 07301104 EFIS: 0714000009 |
---|---|
DIST-CO-RTE-PM | 07-LA-60,710-710-R2.8/11.8, 24.1/25.1 |
Award Date | 06/03/2019 |
Closeout Date | 10/17/2023 |
Work Description | Roadway ex, place jointed plain concrete pavement & concrete barrieres |
Location Description | In Los Angeles County at avocado Heights on Route 60 from 0.5 Mile west of Route 60/710 Separation to Route 60/605 Separation AND on Route 710 from 0.5 miles south of Route 710/60 Separation to 0.5 mile north of Route 710/60 Separation. |
QA Service Level | 1 (Verified on 06/25/2019) |
Sample Information
Sample Taken Date | 09/04/2019 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/06/2019 |
Sample type | Verification | A brief description of the sample | Type III Cement |
The quantity of what the sample constitutes | 15 lbs | From where was the sample collected | Job Site |
First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM194902 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | Mitsubishi |
---|---|---|---|
Mill | Cushenbury | Type of Cementitious Material | Type II Cement |
Test Details
DIME Sample ID: 2019-09-04-7
DIME Test ID: 2019-09-04-7-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Test Release Date: 2019-10-08
Test Results
Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 09/12/2019
Age of specimen: 3 days
The amount of flow : 108 %
The amount of water used : 42.7 %
Compressive strength of 1st specimen : 4788 psi
Compressive strength of 2nd specimen: 4899 psi
Compressive strength of 3rd specimen : 5006 psi
Average Compressive strength (to nearest 10 psi): 4900 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2019 ✔