Summary for Test 2019-05-14-8-9

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214341
DEA: 081J2004
EFIS: 0817000237
DIST-CO-RTE-PM08-SBD-15-R21.5/R22.0
Award Date11/16/2021
Closeout DateNot set
Work DescriptionEXTEND DECELARATION LANE
Location DescriptionSAN BERNARDINO COUNTY NEAR HESPERIA FROM 0.1 MILE NORTH OF ROUTE 15/138 SEPARATION TO GISH OVERHEAD
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date05/14/2019 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/12/2019
Sample typePer Request A brief description of the sampleSoil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byShadi Last name of sampler or witnessed byDweab
Title of samplerTE Telephone number of sampler657-328-6367
Laboratory sample identification8610 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberS-17300-2
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedR-19-003, I-15 SB, PM 21.5-22.0
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-05-14-8
DIME Test ID: 2019-05-14-8-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-20

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 06/17/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 1400 Ohms
Soil sample temperature: 24.2 C
Soil box constant: 1
pH of soil: 10.54
Minimum soil resistance corrected to 15.5: 1705 Ohms
Minimum soil resistivity at 15.5: 1705 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): Estimated Life=31 years

Test was verified on 9/20/2019