Summary for Test 2019-09-06-3-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213750
DEA: 120K0224
EFIS: 1214000097
DIST-CO-RTE-PM12-ORA-5-14.5/17.1
Award Date03/05/2019
Closeout DateNot set
Work DescriptionSouth County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/15/2019)

Sample Information

Sample Taken Date09/06/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/06/2019
Sample typeQuality Assurance A brief description of the sample#7 x 6'-6" Dia Hoops
The quantity of what the sample constitutes2 Lot (302 pcs) From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler5599740870
Laboratory sample identification Linked DIME Sample ID2019-09-06-1
The fabricator/manufacturer/facility nameTNT Rebar Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-054-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateService Rebar Heat Number(s)033608
Hoop Manufacturer Lot Number(s)lot 1-2 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop6'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel California
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2019-09-06-3
DIME Test ID: 2019-09-06-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-09-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/13/2019
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1127/22mm0.660289.89100483Brittle Brake NO Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): Brittle Brake NO Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/13/2019