Summary for Test 2019-09-06-3-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213750 DEA: 120K0224 EFIS: 1214000097 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-14.5/17.1 |
Award Date | 03/05/2019 |
Closeout Date | Not set |
Work Description | South County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS. |
Location Description | ORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING |
QA Service Level | 1 (Verified on 04/15/2019) |
Sample Information
Sample Taken Date | 09/06/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/06/2019 |
Sample type | Quality Assurance | A brief description of the sample | #7 x 6'-6" Dia Hoops |
The quantity of what the sample constitutes | 2 Lot (302 pcs) | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Osiel | Last name of sampler or witnessed by | Ramirez |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 5599740870 |
Laboratory sample identification | Linked DIME Sample ID | 2019-09-06-1 | |
The fabricator/manufacturer/facility name | TNT Rebar Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L123-054-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | 033608 |
Hoop Manufacturer Lot Number(s) | lot 1-2 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 7 |
Diameter of Hoop | 6'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel California |
Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-09-06-3
DIME Test ID: 2019-09-06-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-09-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/13/2019
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 2 | 7/22mm | 0.6 | 60289.89 | 100483 | Brittle Brake NO Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Brittle Brake NO Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 9/13/2019 ✔