Summary for Test 2019-07-26-16-9

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 212603
DEA: 07304604
EFIS: 0714000073
DIST-CO-RTE-PM07-LA-105-R0.5/R18.0
Award Date11/09/2017
Closeout Date01/28/2021
Work DescriptionUPGRADE EXISTING TRANSPORTATION MANAGEMENT SYSTEM ELEMENTS.
Location DescriptionLOS ANGELES COUNTY FROM ROUTE 1/105 SEPARATION IN EL SEGUNDO TO HOXIE AVENUE UNDERCROSSING IN NORWALK
QA Service Level1 (Verified on 06/18/2019)

Sample Information

Sample Taken Date07/26/2019 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/07/2019
Sample typeAnnual Source Testing A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes1 Bags From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byHindman
Title of samplerQuality Control Telephone number of sampler951-493-6500
Laboratory sample identification8671 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons - Cabazon Transportation Laboratory (TL) NumberC-19-000012
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0008::CABAZON QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile at plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-07-26-16
DIME Test ID: 2019-07-26-16-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-09-05

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Sebastian Ferrer
Date of test: 08/22/2019
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 81 %
Cumulative percent passing the #16 sieve: 58 %
Cumulative percent passing the #30 sieve: 36 %
Cumulative percent passing the #50 sieve: 19 %
Cumulative percent passing the #100 sieve: 8 %
Cumulative percent passing the #200 sieve: 5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/5/2019