Summary for Test 2019-08-21-6-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212244 DEA: 044G8404 EFIS: 0413000051 |
---|---|
DIST-CO-RTE-PM | 04-NAP-128-20.1/20.4 |
Award Date | 02/19/2019 |
Closeout Date | 06/27/2023 |
Work Description | REPLACE CAPELL CREEK BRIDGE |
Location Description | NAPA COUNTY ABOUT 15 MILES EAST OF RUTHERFORD FROM 1.1 MILES EAST OF KNOXVILLE ROAD TO 0.3 MILE WEST OF CAPELL VALLEY CREST |
QA Service Level | 1 (Verified on 05/20/2017) |
Sample Information
Sample Taken Date | 08/21/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2019 |
Sample type | Department Acceptance | A brief description of the sample | A325 HDG bolt assemblies |
The quantity of what the sample constitutes | 3 ea assembly | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Parr |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | (510) 385-5910 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Acrow Bridge | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-039-19 | Structure unique identifier | |
Structure name | Cappell Creek Bridge |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | ||
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | Nut Specification | A563 | |
Washer Specification | F436 | Finish | Hot Dipped Galvanized |
Diameter/Size | Bolt Mfg. Lot Number | ||
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-08-21-6
DIME Test ID: 2019-08-21-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-09-16
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 09/04/2019
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2A | 409581A | 1.0000 | 89823 | 399.55 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 9/16/2019 ✔