Summary for Test 2019-04-17-54-11

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/17/2019 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/18/2019
Sample typeVerification A brief description of the sample3/4" HMA - A
The quantity of what the sample constitutes1 From where was the sample collectedSource
First name of sampler or witnessed byIggy Last name of sampler or witnessed byHerrera
Title of sampler Telephone number of sampler
Laboratory sample identification19-JMF-0118 replace with 19-JMF-0129 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Construction Company Vernalis Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0002::VERNALIS
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-04-17-54
DIME Test ID: 2019-04-17-54-11
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-08-30

Test Results


Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 08/21/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500.1 grams
Mass of the pycnometer with water and aggregate (C): 984.6 grams
Mass of the pycnometer with water (B): 675.6 grams
Mass of the oven dried sample (before pycnometer) (A): 489.2 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.1 grams
Mass of the oven dry aggregate (for absorption) (A): 489.2 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.560
Bulk specific gravity (SSD Basis): 2.617
Apparent specific gravity: 2.715
Absorption: 2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/30/2019