Summary for Test 2019-08-20-8-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214283
DEA: 044Q0304
EFIS: 0419000306
DIST-CO-RTE-PM04-SON-1-11.2, 11.20
Award Date05/01/2019
Closeout Date06/20/2022
Work DescriptionREPLACE FAILED 60" CMP CULVERT WITH 10'x10' PRECAST REINFORCED CONCRETE BOX
Location DescriptionNot set
QA Service Level1 (Verified on 08/19/2019)

Sample Information

Sample Taken Date08/20/2019 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/22/2019
Sample typeQuality Assurance A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byDavid Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Dayton Superior Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size6 Coupler ModelBar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A180949 Rebar Heat Number(s)9001331
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2019-08-20-8
DIME Test ID: 2019-08-20-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2019-09-04

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 08/28/2019
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 6/19mmNA-0.00150.444082992792Service Splicebewing

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/4/2019