Summary for Test 2019-08-08-13-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | DEA: No Project |
|---|---|
| DIST-CO-RTE-PM | --- |
| Award Date | Not set |
| Closeout Date | 11/01/2022 |
| Work Description | Special project identifier for material not associated with a project |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/08/2019 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/13/2019 | Sample type | Stock |
| A brief description of the sample | 5/8"-11 x 12" DES HDG Threaded 4" both ends | The quantity of what the sample constitutes | 178 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Steve |
| Last name of sampler or witnessed by | Hall | Title of sampler | CT METS QA INSPECTOR |
| Telephone number of sampler | 6466327821 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | A and M Nut and Bolt | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3085619 75072729 176414 | Nut Mfg. Lot Number(s) | |
| Washer Mfg. Lot Number(s) | Bolt Specification | ASTM F1554-15 Gr55 | |
| Bolt Length(s) | Unknown | Nut Specification | ASTM A194 |
| Washer Specification | F436 | Finish | |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-08-08-13
DIME Test ID: 2019-08-08-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-08-22
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 08/20/2019
UTM: 450kip
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1B | UNC 5/8 | 16850 | 16850.29 | 0.00 | F1554 GR 55 5/8 Stud | fsaylor |
General comments (publicly viewable) (Max 1000 characters): F1554 GR 55 5/8 Stud
Test Graph
Source: Bluehill Data Point FileTest was verified on 8/22/2019 ✔