Summary for Test 2019-07-30-5-56

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 213267
DEA: 04013584
EFIS: 0416000289
DIST-CO-RTE-PM04-SF-80-8.0/8.3,0.9/1.4
Award Date03/29/2018
Closeout Date12/30/2019
Work DescriptionPier Retention
Location DescriptionIn San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza
QA Service Level1 (Verified on 05/01/2018)

Sample Information

Sample Taken Date07/30/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/31/2019
Sample typeQuality Assurance A brief description of the sampleA325 HDG Bolt
The quantity of what the sample constitutes26, From where was the sample collectedFabricator
First name of sampler or witnessed byRick Last name of sampler or witnessed byBettencourt
Title of samplerQA Inspector Telephone number of sampler2092015432
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTC Steel Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-107-19 Structure unique identifier
Structure namePier Retention Oakland

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100890222, 100793765, 100793042, 10552460-66, 10472160-58, 10556940, 10397940, Nut Mfg. Lot Number(s)18-04-008, 18-04-008, 18-04-008,30586-6214705705, 391903A, 30380-S-189067, 29633-75073529
Washer Mfg. Lot Number(s)0119-045,0119-045,0119-045, 0419-143, 1018-988, 0319-116, 1218-036, Bolt SpecificationA325
Bolt Length(s)2", 1-3/4", 1-1/4", 2", 4-1/2", 4", 3" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1/2", 1/2", 1/2", 1", 7/8", 3/4", 5/8" Bolt Mfg. Lot Number403427A,411456A,413210B, 811609, 780909, 8119
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-07-30-5
DIME Test ID: 2019-07-30-5-56
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-08-14

Test Results


Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 08/13/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 0119-045
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: F436 TSI
Size: .5 in
Bolt Length: no data
Measurement Average: 4.9 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/14/2019