Summary for Test 2019-08-05-5-1
Test performed: ASTM A722-15Project Information
Project Identifiers | Project ID: 3825 DEA: 07138204 EFIS: 0700000142 |
---|---|
DIST-CO-RTE-PM | 07-LA-47,103-3.5/4.6,0.0/1.1 |
Award Date | 06/30/2011 |
Closeout Date | 07/14/2022 |
Work Description | REPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS. |
Location Description | LOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD |
QA Service Level | 1 (Verified on 03/29/2012) |
Sample Information
Sample Taken Date | 08/05/2019 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/05/2019 |
Sample type | Quality Assurance | A brief description of the sample | 1 3/8" threaded bar |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Raymond | Last name of sampler or witnessed by | Aludino |
Title of sampler | QA | Telephone number of sampler | 9167300054 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | DSI | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unkown | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Plain | Rebar Size | |
Nut Specification for Threaded Bar | A519 | System Manufacturer | Gerdau |
Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
Coating Standards | Uncoated | Bar Heat Number(s) | 6214910706 |
Nut Heat Number(s) | 072074632 | Bar Lot Number | Unknown |
Nut Lot Number | Unknown | Coupler Heat Number(s) | Unknown |
Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2019-08-05-5
DIME Test ID: 2019-08-05-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2019-08-16
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/12/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | A722 DSI 1.375\" Threaded Bar and Nut | NA | 1.231 | 164918 | 148995 | 0 | 34.3 | A722 Threaded Bar and Nut | Brian |
General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/16/2019 ✔