Summary for Test 2019-07-30-10-2
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 213267 DEA: 04013584 EFIS: 0416000289 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-8.0/8.3,0.9/1.4 |
Award Date | 03/29/2018 |
Closeout Date | 12/30/2019 |
Work Description | Pier Retention |
Location Description | In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza |
QA Service Level | 1 (Verified on 05/01/2018) |
Sample Information
Sample Taken Date | 07/30/2019 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/05/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Bolt |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Gray |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Unytite Dynamic | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | 532-311-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 100794827 | Nut Mfg. Lot Number(s) | 30380-S-189067 |
Washer Mfg. Lot Number(s) | 0319-116 | Bolt Specification | F1554 |
Bolt Length(s) | 12" | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | .75" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-07-30-10
DIME Test ID: 2019-07-30-10-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-08-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 08/07/2019
UTM: 67KIP
Temperature: 72 f
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 100794827 | 0.503 | 0.199 | 136475 | 140130 | 21.4 | Steve |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/7/2019 ✔