Summary for Test 2019-07-29-4-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date07/29/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/29/2019
Sample typeQuality Assurance A brief description of the sampleA490 Fastener Assembly
The quantity of what the sample constitutes30 From where was the sample collectedJob Site
First name of sampler or witnessed byNicholas Last name of sampler or witnessed byHoffmann
Title of samplerIQA Inspector Telephone number of sampler5105429827
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLeJeune Bolt Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameGERALD DESMOND BRIDGE

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bolt 10558400 Nut 6214661005 Washer 140647 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt Specification1 1/4-7 x 5 1/2 F3125 Grade A490
Bolt Length(s)5 1/2 Nut Specification1 1/4-7 A563 DH
Washer Specification1 1/4 F436 Finish
Diameter/SizeUnknown Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-07-29-4
DIME Test ID: 2019-07-29-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-08-07

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 08/06/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A28748-10558400Z1.25\"158326704.36A490Steve

General comments (publicly viewable) (Max 1000 characters): A490
Test Graph
Source: Partner Data Point File

Test was verified on 8/7/2019