Summary for Test 2019-07-30-9-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 212824 DEA: 051C3704 EFIS: 0512000135 |
---|---|
DIST-CO-RTE-PM | 05-SLO-101-16.4 |
Award Date | 11/20/2018 |
Closeout Date | 08/23/2021 |
Work Description | PISMO CREEK SCOUR REPAIR PROJECT (BR 49-0015K) |
Location Description | IN SAN LUIS OBISPO COUNTY IN PISMO AT PISMO CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/29/2019) |
Sample Information
Sample Taken Date | 07/30/2019 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/02/2019 |
Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Casting |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | DSI Dotson Iron | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 2039 |
---|---|---|---|
Part Number (s) | 68 19 246 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Dotson iron casting |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2019-07-30-9
DIME Test ID: 2019-07-30-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-08-05
Test Results
Number of Samples: 1
Input Type: Calculated
Tester's full name: Fred
Date of test: 08/05/2019
UTM: 67KIP
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2039 | 0.497 | 0.194 | 48410 | 78680 | 12 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 8/5/2019 ✔