Summary for Test 2019-07-23-8-6
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 212889 DEA: 073009U4 EFIS: 0714000238 |
---|---|
DIST-CO-RTE-PM | 07-LA-110-R0.7/24.1 |
Award Date | 04/03/2018 |
Closeout Date | 06/30/2021 |
Work Description | REPLACE CONCRETE PAVEMENT, COLD PLANE AND PLACE HMA PAVEMENT. |
Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES AND CARSON FROM GAFFEY STREET TO 0.1 MILE SOUTH OF COLLEGE STREET OVERCROSSING |
QA Service Level | 1 (Verified on 06/21/2018) |
Sample Information
Sample Taken Date | 07/23/2019 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/24/2019 |
Sample type | Verification | A brief description of the sample | 3/4 RHMA-G-SP |
The quantity of what the sample constitutes | PSE 3 bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Loi | Last name of sampler or witnessed by | Nguyen |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0441G-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | All American Asphalt Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0005::ALL AMERICAN ASPHALT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 RHMA-G-SP | The fabricator/manufacturer designation for the sample | 106835 |
The plant number | Unknown | A detailed description of where the material sample was collected | Belt Cut at All American Corona Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-07-23-8
DIME Test ID: 2019-07-23-8-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-08-22
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Jose Guzman
Date of test: 07/26/2019
Clay Level (Test 1): 4.8
Sand Level (Test 1): 3.7
Clay Level (Test 2): 4.9
Sand Level (Test 2): 3.9
Clay Level (Test 3): 5
Sand Level (Test 3): 3.9
Sand Equivalent (Test 1): 78
Sand Equivalent (Test 2): 80
Sand Equivalent (Test 3): 78
Sand Equivalent: 79
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/22/2019 ✔