Summary for Test 2019-07-22-2-5

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212785
DEA: 04014114
EFIS: 0414000436
DIST-CO-RTE-PM04-ALA-80-2.1
Award Date04/06/2018
Closeout Date01/21/2021
Work DescriptionCONSTRUCT MAINTENANCE BUILDING AND PARKING LOT
Location DescriptionIN ALAMEDA COUNTY IN OAKLAND AT THE SAN FRANCISCO-OAKLAND BAY BRIDGE MAINTENANCE YARD
QA Service Level1 (Verified on 02/13/2018)

Sample Information

Sample Taken Date07/22/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/26/2019
Sample typeQuality Assurance A brief description of the sample#4 Flash Welded Hoops
The quantity of what the sample constitutes3 lots From where was the sample collectedFabricator
First name of sampler or witnessed byHitesh Last name of sampler or witnessed byPatel
Title of samplerQuality Assurance Inspector Telephone number of sampler9168691602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL131-157-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4082952
Hoop Manufacturer Lot Number(s)Lots 1, 2, and 7 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2019-07-22-2
DIME Test ID: 2019-07-22-2-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-07-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/29/2019
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
122#4/13mm0.21957097850Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/30/2019