Summary for Test 2019-06-11-20-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 |
---|---|
DIST-CO-RTE-PM | 02-SIS-5-2.7/R11.4 |
Award Date | 03/12/2018 |
Closeout Date | 10/05/2020 |
Work Description | RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS |
Location Description | SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS |
QA Service Level | 1 (Verified on 04/04/2018) |
Sample Information
Sample Taken Date | 06/11/2019 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/12/2019 |
Sample type | Verification | A brief description of the sample | RAP, 3/8-inch |
The quantity of what the sample constitutes | JMF Renewal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Carmichael |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D77929B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Fawndale Rock and Asphalt | Transportation Laboratory (TL) Number | 991051 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Fawndale Rock and Asphalt |
---|---|---|---|
Aggregate Size | Fine | Aggregate Source | Unknown |
RAP Stockpile | Stockpile Size (tons) | Unknown | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2019-06-11-20
DIME Test ID: 2019-06-11-20-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-07-26
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 06/13/2019
Method Performed: no data
Mass of container filled with water: 7341 grams
Mass of oven-dry sample in air for Sample 1: 1600 grams
Mass of container filled with the sample and water for Sample 1: 8305 grams
Temperature of Water: 24 °F
Specific Gravity for Sample 1: 2.515
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/26/2019 ✔