Summary for Test 2019-06-05-24-9

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 212888
DEA: 07202124
EFIS: 0700020870
DIST-CO-RTE-PM07-LA-710-20.9/24.6
Award Date02/16/2018
Closeout Date05/04/2022
Work DescriptionPAVEMENT REHABILITATION AND BRIDGE WIDENING
Location DescriptionLOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING
QA Service Level1 (Verified on 03/29/2018)

Sample Information

Sample Taken Date06/05/2019 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2019
Sample typeAnnual Source Testing A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of sampler Telephone number of sampler
Laboratory sample identification8605 Linked DIME Sample ID
The fabricator/manufacturer/facility nameUnited Rock Products Irwindale Transportation Laboratory (TL) NumberNone
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0015
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-05-24
DIME Test ID: 2019-06-05-24-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2019-07-09

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 07/03/2019
Temperature correction: 0
Temperature of solution: 73
Clay reading (test 1): 4.9
Sand reading (test 1): 4.4
Clay reading (test 2): 4.9
Sand reading (test 2): 4.4
Sand equivalent (test 1): 90
Sand equivalent (test 2): 90
Sand equivalent before temperature correction: 90
Sand equivalent after temperature correction: 90
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/9/2019