Summary for Test 2014-02-05-3889-1
Test performed: CTM 643-June 2007Project Information
Project Identifiers | Project ID: 209616 DEA: 024E4404 EFIS: 0200020285 |
---|---|
DIST-CO-RTE-PM | 02-MOD-139-R10.7/28.0 |
Award Date | 11/24/2015 |
Closeout Date | 03/22/2017 |
Work Description | FULL DEPTH PAVEMENT RECLAMATION, HMA AND RUBBERIZED HMA. |
Location Description | IN MODOC COUNTY ABOUT 17 MILES SOUTH OF NEWELL FROM 0.1 MILE NORTHOF BOLES ROAD TO 0.1 MILE SOUTH OF PEREZ ROAD. |
QA Service Level | 1 (Verified on 06/20/2014) |
Sample Information
Sample Taken Date | 02/05/2014 | Sample Unique Key | 3889 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/10/2014 |
Sample type | Preliminary | A brief description of the sample | Native Soil |
The quantity of what the sample constitutes | 1 container | From where was the sample collected | Source |
First name of sampler or witnessed by | Joel | Last name of sampler or witnessed by | Gasik |
Title of sampler | ADME | Telephone number of sampler | (530) 225-3384 |
Laboratory sample identification | D75701 / 847661 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Native | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Not set |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Not set | A detailed description of where the material sample was collected | Streambed at MOD-139-12.16 (0-1 ft below OG.) |
Where the material sample would have been placed if not sampled | Not set |
Test Details
DIME Sample ID: 2014-02-05-3889
DIME Test ID: 2014-02-05-3889-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2014-07-25
Test Results
The test method used?: Laboratory Resistivity Test
Input Type: Calculated
Tester's full name: Marvin Perriseau
Date of test: 02/10/2014
General comments (publicly viewable) (Max 1000 characters): Water was not tested. Values of 0.00 were input when the form incorrectly required a field to be filled.
Test was verified on 7/25/2014 ✔