Summary for Test 2019-06-26-9-1

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213551
DEA: 080K2934
EFIS: 0812000100
DIST-CO-RTE-PM08-SBD-10-R36.8/R39.2
Award Date11/09/2018
Closeout Date09/15/2021
Work DescriptionPAVEMENT REHABILITATION AND CONTINUOUSLY REINFORCED CONCRETE PAVEMENT
Location DescriptionSAN BERNARDINO COUNTY IN YUCAIPA FROM 0.2 MILE WEST OF LIVE OAK CANYON ROAD TO COUNTY LINE ROAD UNDERCROSSING
QA Service Level1 (Verified on 12/31/2018)

Sample Information

Sample Taken Date06/26/2019 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/26/2019
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R12
The quantity of what the sample constitutesPSE 11 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byMatich Lytle Creek Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0365A-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMatich-Lytle Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040::LYTLE CREEK
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleLHP-62D
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-26-9
DIME Test ID: 2019-06-26-9-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-07-01

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: I. NAJJAR
Date of test: 06/26/2019
Sand Equivalent (Test 1): 69
Sand Equivalent (Test 2): 70
Sand Equivalent (Test 3): 69
Sand Equivalent: 70
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2019