Summary for Test 2019-06-12-3-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 213650
DEA: 081E8504
EFIS: 0814000114
DIST-CO-RTE-PM08-SBD-142-0.0/5.8
Award Date11/19/2018
Closeout Date08/28/2020
Work DescriptionCOLD PLANE/OVERLAY, HMA DIKES, INSTALL MGS AND DRAINAGE FACILITIES
Location DescriptionSAN BERNARDINO COUNTY IN AND NEAR CHINO HILLS FROM ORANGE COUNTY LINE TO ROUTE 142/71 SEPARATION.
QA Service Level1 (Verified on 04/16/2019)

Sample Information

Sample Taken Date06/12/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/14/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesPSE 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byAll American Corona Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0348G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample106835
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-12-3
DIME Test ID: 2019-06-12-3-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-07-03

Test Results


Input Type: Measured
Tester's full name: Nader Rashidi
Date of test: 06/18/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 968.2 grams
Mass of the pycnometer with water (B): 653.9 grams
Mass of the oven dried sample (before pycnometer) (A): 491.3 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.3 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.646
Bulk specific gravity (SSD Basis): 2.693
Apparent specific gravity: 2.776
Absorption: 1.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/3/2019