Summary for Test 2019-05-15-14-13
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 213309 DEA: 081H0904 EFIS: 0816000141 |
---|---|
DIST-CO-RTE-PM | 08-RIV-15-43.5 |
Award Date | 06/11/2018 |
Closeout Date | 12/12/2019 |
Work Description | CONSTRUCT A SECOND LEFT-TURN LANE |
Location Description | RIVERSIDE COUNTY IN NORCO AT SECOND STREET UNDERCROSSING. |
QA Service Level | 1 (Verified on 09/05/2018) |
Sample Information
Sample Taken Date | 05/15/2019 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/15/2019 |
Sample type | Per Request | A brief description of the sample | Clss 2 Aggregate Base |
The quantity of what the sample constitutes | 1 bucket | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Kohnson | Last name of sampler or witnessed by | Chan |
Title of sampler | Transportation Engineer | Telephone number of sampler | |
Laboratory sample identification | 8596 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C 703419 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | I-15 near 2nd street |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-05-15-14
DIME Test ID: 2019-05-15-14-13
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2019-06-12
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 05/17/2019
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.8
Sand reading (test 1): 3.8
Clay reading (test 2): 5.8
Sand reading (test 2): 3.7
Sand equivalent (test 1): 66
Sand equivalent (test 2): 64
Sand equivalent before temperature correction: 65
Sand equivalent after temperature correction: 65
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/5/2019 ✔