Summary for Test 2019-04-25-18-3
Test performed: AASHTO T275-07r12Project Information
Project Identifiers | Project ID: 210808 DEA: 020E0904 EFIS: 0200000016 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R29.3/R31.1,R45.0/R45.8 |
Award Date | 02/03/2016 |
Closeout Date | 10/21/2020 |
Work Description | REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT |
Location Description | IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE. |
QA Service Level | 1 (Verified on 09/23/2015) |
Sample Information
Sample Taken Date | 04/25/2019 | Sample Unique Key | 18 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/25/2019 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (eq. PG 64-28 M) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Josh | Last name of sampler or witnessed by | Williams |
Title of sampler | Consultant | Telephone number of sampler | |
Laboratory sample identification | D77851 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Northstate Asphalt | Transportation Laboratory (TL) Number | 001901 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 0 |
Sublot number | 0 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-25-18
DIME Test ID: 2019-04-25-18-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2019-05-29
Test Results
Number of tests: 3
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 04/26/2019
Mass of the dry specimen in air: 4553.7 g
Mass of the dry specimen plus paraffin coating in air: 4610.1 g
Mass of the dry specimen plus paraffin coating in water: 2630.1 g
Specific gravity of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 2 of the dry specimen in air: 4562.2 g
Mass 2 of the dry specimen plus paraffin coating in air: 4619 g
Mass 2 of the dry specimen plus paraffin coating in water: 2640 g
Specific gravity 2 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Mass 3 of the dry specimen in air: 4577 g
Mass 3 of the dry specimen plus paraffin coating in air: 4633.9 g
Mass 3 of the dry specimen plus paraffin coating in water: 2648.3 g
Specific gravity 3 of the paraffin at 25 ± 1°C (77 ± 1.8°F): 0.9
Bulk Specific Gravity: 2.375
Bulk Specific Gravity 2: 2.381
Bulk Specific Gravity 3: 2.381
Average Bulk Specific Gravity: 2.379
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/29/2019 ✔