Summary for Test 2019-05-10-6-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
Award Date | 03/22/2018 |
Closeout Date | 07/24/2023 |
Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
Location Description | SFOBB WEST SPAN |
QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
Sample Taken Date | 05/10/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2019 |
Sample type | Quality Assurance | A brief description of the sample | 1" x 3" A325 Bolt, nut and washer assemblies |
The quantity of what the sample constitutes | 135ea | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | California Engineering Contractor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-038-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0113077 |
---|---|---|---|
Heat Number(s) | 100893078 | Nut Mfg. Lot Number(s) | 28578-6214658702 |
Washer Mfg. Lot Number(s) | D1209 | Bolt Specification | A325 |
Bolt Length(s) | 3" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | Hot Dip Galvanized |
Diameter/Size | 1" | Bolt Mfg. Lot Number | BG1251 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-05-10-6
DIME Test ID: 2019-05-10-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-05-31
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 05/20/2019
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | BG1251 | 1\" | 85420 | 380 | 10 | A325 | Steve |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 5/24/2019 ✔