Summary for Test 2019-04-12-12-7
Test performed: AASHTO T324-14Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/12/2019 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2019 |
Sample type | Verification | A brief description of the sample | 3/4 inch Type A HMA (eq. PG 70-10) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Martiniano | Last name of sampler or witnessed by | Ruiz |
Title of sampler | Mat and Res Eng Aso Spc | Telephone number of sampler | 5592894416 |
Laboratory sample identification | 019-005 | Linked DIME Sample ID | NA |
The fabricator/manufacturer/facility name | Deer Creek Porterville | Transportation Laboratory (TL) Number | HDQTRS Lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-12-12
DIME Test ID: 2019-04-12-12-7
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2019-05-23
Test Results
Input Type: Measured
Tester's full name: Frank Chavez
Date of test: 04/29/2019
HMA Production: Field Plant Produced
Specified number of passes at 12.7 mm: 20000
Specified number of passes at inflection point: 12500
Type and Amount of Anti-Stripping Additive: N/A
Compaction Method: SGC Cylindrical Specimen
Test Temperature: 131 F
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 20000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 20000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 4.46 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.79 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
General comments (publicly viewable) (Max 1000 characters): t-327
Test was verified on 5/16/2019 ✔