Summary for Test 2019-04-17-25-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 213720 DEA: 024H2004 EFIS: 0218000094 |
---|---|
DIST-CO-RTE-PM | 02-SHA-89-26.3/29.2 |
Award Date | 12/19/2018 |
Closeout Date | 08/06/2019 |
Work Description | PAVEMENT OVERLAY |
Location Description | SHASTA COUNTY ABOUT 10 MILES NORTH OF BURNEY FROM 0.3 MILE NORTH OF CLARK CREEK ROAD TO LAKE BRITTON BRIDGE |
QA Service Level | 1 (Verified on 01/04/2019) |
Sample Information
Sample Taken Date | 04/17/2019 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/18/2019 |
Sample type | Verification | A brief description of the sample | -3/8 inch RAP |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D77830A | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Shaw Pit Facility | Transportation Laboratory (TL) Number | 853328 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Shaw Pit Facility |
---|---|---|---|
Aggregate Size | 3/8-inch | Aggregate Source | Unknown |
RAP Stockpile | Stockpile Size (tons) | Unknown | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-17-25
DIME Test ID: 2019-04-17-25-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-05-08
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 04/19/2019
Method Performed: no data
Mass of container filled with water: 7372.0 grams
Mass of oven-dry sample in air for Sample 1: 1570.0 grams
Mass of container filled with the sample and water for Sample 1: 8327.0 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.552
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/8/2019 ✔