Summary for Test 2019-04-01-25-7
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 212753 DEA: 020H7604 EFIS: 0215000086 |
---|---|
DIST-CO-RTE-PM | 02-LAS,PLU-VAR-VAR |
Award Date | 03/28/2019 |
Closeout Date | 09/02/2020 |
Work Description | FULL DEPTH RECLAMATION AND DRAINAGE REHABILITATION |
Location Description | LASSEN AND PLUMAS COUNTIES AT AND NEAR CHILCOOT FROM 0.9 MILE WEST OF SUMMIT SCHOOL DRIVE TO 0.7 MILE EAST OF ROUTE 395 |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 04/01/2019 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/01/2019 |
Sample type | Quality Control | A brief description of the sample | Combined Aggregate |
The quantity of what the sample constitutes | Mix Design | From where was the sample collected | Source |
First name of sampler or witnessed by | Ted | Last name of sampler or witnessed by | Kinsey |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Hat Creek - Ward Lake | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-18-0008::WARD LAKE PIT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Plant Stockpile |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-01-25
DIME Test ID: 2019-04-01-25-7
Testing Lab: CGI Technical Services, Incorporated
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-05-08
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: A
Determination: By Number
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Ted Kinsey
Date of test: 04/24/2019
Weighted percentage of particles (by number) that were flat: 1 %
Weighted percentage of particles (by number) that were elongated: 1 %
Weighted percentage of particles (by number) that were both flat and elongated: 1 %
Weighted percentage of particles (by number) that were neither flat nor elongated: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/8/2019 ✔