Summary for Test 2019-03-25-25-4
Test performed: AASHTO T209-12
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/25/2019 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/29/2019 |
Sample type | Verification | A brief description of the sample | 1/2 inch Type A (PG 64-10) (Dispute Resolution of JMF) |
The quantity of what the sample constitutes | Dispute Resolution of JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Mark | Last name of sampler or witnessed by | Huddleston |
Title of sampler | Mat and Res Eng Aso | Telephone number of sampler | |
Laboratory sample identification | 019-006 | Linked DIME Sample ID | NA |
The fabricator/manufacturer/facility name | Papich Construction | Transportation Laboratory (TL) Number | HDQTRS Lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-03-25-25
DIME Test ID: 2019-03-25-25-4
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-05-15
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Water
Input Type: Measured
Tester's full name: Frank Chavez
Date of test: 05/01/2019
Method Performed: no data
Mass of oven-dry sample in air for Sample 1: 1608 grams
Mass of sample in water for Sample 1: 953 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.454
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/8/2019 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.