Summary for Test 2019-03-11-16-8

Test performed: CTM 211-May 2010

Project Information

Project IdentifiersProject ID: 213647
DEA: 080N9724
EFIS: 0815000102
DIST-CO-RTE-PM08-SBD-395-35.5/39.1
Award Date12/03/2018
Closeout Date12/02/2019
Work DescriptionCONSTRUCT MEDIAN AND WIDENING SHOULDER
Location DescriptionSAN BERNARDINO COUNTY NEAR ADELANTO FROM 1.3 MILES SOUTH TO 2.3 MILES NORTH OF KRAMER ROAD
QA Service Level1 (Verified on 03/05/2019)

Sample Information

Sample Taken Date03/11/2019 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/11/2019
Sample typeAnnual Source Testing A brief description of the sample3/8" PCC Aggregate
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byStefan Last name of sampler or witnessed byReder
Title of sampler Telephone number of sampler
Laboratory sample identification8538 Linked DIME Sample ID2019-03-11-15-15
The fabricator/manufacturer/facility nameAgcon- Oro Grande Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0046::AGCON, INC.
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-11-16
DIME Test ID: 2019-03-11-16-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
Test Release Date: 2019-05-08

Test Results


How many revolutions are required?: 500 Revolution Test
Input Type: Calculated
Tester's full name: Friday Ofoegbu
Date of test: 03/21/2019
Grading: C
Percent wear: 30 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/1/2019