Summary for Test 2019-03-27-19-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/27/2019 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/12/2019 |
Sample type | Quality Assurance | A brief description of the sample | F1554 anchor rods |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Andrew | Last name of sampler or witnessed by | Bellon |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ASI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 6213649004 6214399712 6214815409 | Nut Mfg. Lot Number(s) | 409160A DDXO DDXS |
Washer Mfg. Lot Number(s) | 0418826 0917626 1117687 | Bolt Specification | F1554 GR 55 |
Bolt Length(s) | 18" 30" 32" | Nut Specification | A194 A563 |
Washer Specification | F436 HDG | Finish | HDG |
Diameter/Size | 1" 1.75" 2" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-03-27-19
DIME Test ID: 2019-03-27-19-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-05-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/16/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | NA | 1\" | 93189 | 414.53 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 4/26/2019 ✔