Summary for Test 2014-02-05-7307672-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 3958 DEA: 07215914 EFIS: 0700001831 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-1.2/2.1 |
Award Date | 12/31/1969 |
Closeout Date | 06/14/2016 |
Work Description | WIDEN AND REALIGN FREEWAY AND RECONSTRUCT OVERCROSSING STRUCTURE. |
Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS FROM 0.3 MILE SOUTH OF NORTH FORK COYOTE CREEK BRIDGE TO 0.3 MILE NORTH OF MARQUARDT AVENUE AND AT NORWALK HUB AND LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER |
QA Service Level | 1 (Verified on 05/01/2012) |
Sample Information
Sample Taken Date | 02/05/2014 | Sample Unique Key | 7307672 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/05/2014 |
Sample type | Acceptance | A brief description of the sample | Class 3 Aggregate Base |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Other |
First name of sampler or witnessed by | Jose | Last name of sampler or witnessed by | Burbano |
Title of sampler | ARE | Telephone number of sampler | Unknown |
Laboratory sample identification | 4059B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | DR 1 line Sta 84 00 to 86 00 | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Robertsons Anaheim |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | DR 1 line Sta 84 to 86 |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-02-05-7307672
DIME Test ID: 2014-02-05-7307672-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2015-02-20
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Farzin Farah
Date of test: 02/13/2014
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 95 %
Cumulative percent passing the 1/2 in. sieve: 82 %
Cumulative percent passing the 3/8 in. sieve: 75 %
Cumulative percent passing the #4 sieve: 56 %
Cumulative percent passing the #8 sieve: 43 %
Cumulative percent passing the #16 sieve: 32 %
Cumulative percent passing the #30 sieve: 22 %
Cumulative percent passing the #50 sieve: 15 %
Cumulative percent passing the #100 sieve: 11 %
Cumulative percent passing the #200 sieve: 9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔