Test 2019-01-24-12-1 (AASHTO T27-14) Summary
Project Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 | ||
---|---|---|---|
DIST-CO-RTE-PM | 59--- | ||
Work Description | Special project for submitting Sample information for JMF Prequalification Program. | ||
Location Description | Not set |
Sample Information
Sample Taken Date | 1/24/2019 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Quality Control | A brief description of the sample | 3/4 Inch HMA-A |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | Akira | Last name of sampler or witnessed by | Hasegawa |
Title of sampler | Laboratory sample identification | ||
The fabricator/manufacturer/facility name | Deer Creek Porterville | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-54-0021::DEER CREEK QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | HMA Design ID | JMF3512-2019-71-17-1011.247_C |
Test Details
DIME Sample ID: 2019-01-24-12
DIME Test ID: 2019-01-24-12-1
Testing Lab: CT HQ - Hot Mix Asphalt Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-04-16
Test Results
What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Gurpartap Grewal
Date of test: 01/24/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:82 %
Cumulative percent passing the 1/2 in. sieve:41 %
Cumulative percent passing the 3/8 in. sieve:15 %
Cumulative percent passing the 1/4 in. sieve:15 %
Cumulative percent passing the #4 sieve:2 %
Cumulative percent passing the #8 sieve:1 %
Cumulative percent passing the #16 sieve:1 %
Cumulative percent passing the #30 sieve:1 %
Cumulative percent passing the #50 sieve:1 %
Cumulative percent passing the #100 sieve:1 %
Cumulative percent passing the #200 sieve:1 %
General comments (publicly viewable) (Max 1000 characters): Aggregate Gradation Sample 1 T-27 3/4 Crushed
Test was verified on 04/09/2019 ✔