Summary for Test 2019-03-16-3-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 212889
DEA: 073009U4
EFIS: 0714000238
DIST-CO-RTE-PM07-LA-110-R0.7/24.1
Award Date04/03/2018
Closeout Date06/30/2021
Work DescriptionREPLACE CONCRETE PAVEMENT, COLD PLANE AND PLACE HMA PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES AND CARSON FROM GAFFEY STREET TO 0.1 MILE SOUTH OF COLLEGE STREET OVERCROSSING
QA Service Level1 (Verified on 06/21/2018)

Sample Information

Sample Taken Date03/16/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/25/2019
Sample typeVerification A brief description of the sample3/4" HMA-A R15 PG64-10
The quantity of what the sample constitutes20 boxes From where was the sample collectedSource
First name of sampler or witnessed byG Last name of sampler or witnessed byZubieta
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2019-03-16-3
DIME Test ID: 2019-03-16-3-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2019-04-05

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Gustavo Chao
Date of test: 03/28/2019
Specimen Treatment: Untreated
Average Dry Tensile Strength: 245 psi
Average Wet Tensile Strength: 184 psi
Tensile Strength Ratio: 75
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/5/2019