Summary for Test 2019-02-27-1-3
Test performed: CTM 527-February 2014Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/27/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/14/2019 |
Sample type | Acceptance | A brief description of the sample | Rapid Setting Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM194901 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CTS Rapid Set | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Cementitious | Brand | CTS |
---|---|---|---|
Mill | Unknown | Type of Cementitious Material | Rapid Set Cement |
Test Details
DIME Sample ID: 2019-02-27-1
DIME Test ID: 2019-02-27-1-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: CTM 527-February 2014: Method of Test for Expansion in Water and Contraction in Air of Portland Cement Mortar
Test Release Date: 2022-05-11
Test Results
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 03/25/2019
Initial Length of Specimen 1: .2727 in
Expansion Length of Specimen 1: .2730 in
Percent Expansion of Specimen 1: 0.00 %
Contraction Length of Specimen 1: .2720 in
Percent Contraction of Specimen 1: 0.01 %
Initial Length of Specimen 2: .2977 in
Expansion Length of Specimen 2: .2981 in
Percent Expansion of Specimen 2: 0.00 %
Contraction Length of Specimen 2: .2970 in
Percent Contraction of Specimen 2: 0.01 %
Initial Length of Specimen 3: .2391 in
Expansion Length of Specimen 3: .2395 in
Percent Expansion of Specimen 3: 0.00 %
Contraction Length of Specimen 3: .2384 in
Percent Contraction of Specimen 3: 0.01 %
Initial Length of Specimen 4: .2499 in
Expansion Length of Specimen 4: .2502 in
Percent Expansion of Specimen 4: 0.00 %
Contraction Length of Specimen 4: .2492 in
Percent Contraction of Specimen 4: 0.01 %
Average change in length in water: 0.00 %
Average change in length in air: 0.01 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/11/2022 ✔