Summary for Test 2018-11-01-3-3

Test performed: ASTM C109-11
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/01/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/01/2018
Sample typeAnnual Source Testing A brief description of the sampleClass F Flyash
The quantity of what the sample constitutes1 Bucket From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationCM185842 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCharah Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandCharah
MillDynegy Miami Fort 7 Type of Cementitious MaterialClass F or N Flyash

Test Details

DIME Sample ID: 2018-11-01-3
DIME Test ID: 2018-11-01-3-3
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2020-07-17

Test Results


Will control cubes be used per ASTM C311?: no
Input Type: Measured
Tester's full name: SD
Date of test: 03/19/2019
Age of specimen: 28 days
The amount of flow (In percent): 22 %
The amount of water used (In percent): 44.1 %
Maximum load of 1st specimen (lb): 16897 lb
Maximum load of 2nd specimen (lb): 15671 lb
Maximum load of 3rd specimen (lb): 17730 lb
Cross sectional area loaded of 1st specimen (sq. inch): 4 in^2
Cross sectional area loaded of 2nd specimen (sq. inch): 4 in^2
Cross sectional area loaded of 3rd specimen (sq. inch): 4 in^2
Compressive strength of 1st specimen (psi): 4224 psi
Compressive strength of 2nd specimen (psi): 3918 psi
Compressive strength of 3rd specimen (psi): 4433 psi
Average Compressive strength (to nearest 10 psi): 4190 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day Break
Test Graph
Source: Partner Data Point File
Test graph for Specimen 1 of 3

Source: Partner Data Point File
Test graph for Specimen 2 of 3

Source: Partner Data Point File
Test graph for Specimen 3 of 3

Test was verified on 7/17/2020

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.