Summary for Test 2019-03-01-11-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213078 DEA: 081G6204 EFIS: 0816000031 |
---|---|
DIST-CO-RTE-PM | 08-RIV-10,86-Var |
Award Date | 04/06/2018 |
Closeout Date | 05/10/2019 |
Work Description | COLD PLANE, RHMA-G OVERLAY, REPLACE PRECAST SLAB AND LOCALIZED DIG-OUT |
Location Description | IN RIVERSIDE COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 04/09/2018) |
Sample Information
Sample Taken Date | 03/01/2019 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/04/2019 |
Sample type | Acceptance | A brief description of the sample | 3/4 RHMA-G PG64-16RB (1.0% Lime Slurry |
The quantity of what the sample constitutes | 2 boxes 896.83 tons out | From where was the sample collected | Source |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Oluoha |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0154G-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CCA-Coachella | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 3 |
Sublot number | 11 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-03-01-11
DIME Test ID: 2019-03-01-11-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-03-19
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 03/06/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 7.46 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/12/2019 ✔