Summary for Test 2019-02-11-2-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213442 DEA: 112E1504 EFIS: 1117000179 |
---|---|
DIST-CO-RTE-PM | 11-SD-5-38.1/39.3 |
Award Date | 11/06/2017 |
Closeout Date | 09/20/2021 |
Work Description | (ALTERNATIVE DELIVERY) WETLAND CONSTRUCTION |
Location Description | NEAR STATE HIGHWAY IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 08/28/2018) |
Sample Information
Sample Taken Date | 02/11/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 02/13/2019 |
Sample type | Quality Assurance | A brief description of the sample | #6 Flash Welded Hoops |
The quantity of what the sample constitutes | 230 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110 017-19 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4082089 |
Hoop Manufacturer Lot Number(s) | Lot 1 and Lot 2 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6 |
Diameter of Hoop | 2'-10" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-02-11-2
DIME Test ID: 2019-02-11-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-02-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/19/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #6/19mm | 0.44 | 39290 | 89300 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 2/19/2019 ✔