Summary for Test 2019-02-06-10-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212185
DEA: 024G5204
EFIS: 0214000022
DIST-CO-RTE-PM02-SHA-5-R28.0 - R29.2
Award Date05/21/2018
Closeout Date09/02/2020
Work DescriptionPIT RIVER BRIDGE DECK & CATWALK REHABILITATION
Location DescriptionSHASTA COUNTY ABOUT 6 MILES NORTH OF SHASTA LAKE FROM 0.2 MILE SOUTH TO 0.9 MILE NORTH OF PIT RIVER BRIDGE OVERHEAD
QA Service Level1 (Verified on 06/05/2017)

Sample Information

Sample Taken Date02/06/2019 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/06/2019
Sample typeQuality Assurance A brief description of the sampleA325 Fastener Assembly
The quantity of what the sample constitutes30,26,36,70,54,270,46 From where was the sample collectedFabricator
First name of sampler or witnessed byRichard Last name of sampler or witnessed byBettencourt
Title of samplerQA Inspector Telephone number of sampler209-201-5432
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCK Johnson Industries Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS25-007-19 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)R407066A,R355672A,R378572A,R409547B,R366369A,R416148A,R2982528
Heat Number(s)100888940, 15100087,16100849,18103275,15101674,100890613,11203578 Nut Mfg. Lot Number(s)393695A,363695A,393695A, 413072A,407093A,407093A,407093A,
Washer Mfg. Lot Number(s)C9199M,C9199M,C9199M,0118-742,310706,310706,310706, Bolt SpecificationA325
Bolt Length(s)3",3-1/2",4",2-1/4",2",1-3/4",2-3/4", Nut SpecificationDH
Washer SpecificationF436 FinishMG
Diameter/Size1",1",1",3/4",5/8",5/8",5/8" Bolt Mfg. Lot Number407066A,355672A,378572A,409547B,366369A,41614
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-02-06-10
DIME Test ID: 2019-02-06-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-02-27

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/19/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A407066A1\"87537389.410A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 2/20/2019