Summary for Test 2014-05-21-6005163-2

Test performed: CTM 206-October 2011

Project Information

Project IdentifiersProject ID: 4085
DEA: 07286904
EFIS: 0700020897
DIST-CO-RTE-PM07-LA-60-11.6/R23.6
Award Date12/22/2011
Closeout Date04/02/2015
Work DescriptionREPLACE PCC SLABS & ELECTRICAL LOOPS AND GRIND PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN CITY OF INDUSTRY AND DIAMOND BAR FROM ROUTE 60/605 SEPARATION TO S57/60 SEPARATION
QA Service Level1 (Verified on 05/01/2012)

Sample Information

Sample Taken Date05/21/2014 Sample Unique Key6005163
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/21/2014
Sample typeAnnual Source Testing A brief description of the sample1 Inch Rock
The quantity of what the sample constitutes8 Bags From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identification4146B Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameVulcan Durbin Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0023::DURBIN
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2014-05-21-6005163
DIME Test ID: 2014-05-21-6005163-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate
Test Release Date: 2015-02-20

Test Results


How will the aggregate be used?: portland cement
Input Type: Calculated
Tester's full name: Nader Rashidi
Date of test: 05/30/2014
% Water Absorbed: 0.8 %
Bulk Saturated Surface Dry Specific Gravity: 2.65
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015