Summary for Test 2019-01-18-6-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 212910
DEA: 080K2914
EFIS: 0812000098
DIST-CO-RTE-PM08-SBD-10-30.9/33.3
Award Date03/06/2018
Closeout Date09/04/2019
Work DescriptionLANE REPLACEMENT
Location DescriptionSAN BERNARDINO COUNTY IN REDLANDS FROM ORANGE STREET UNDERCROSSING TO REDLANDS BLVD OFF-RAMP UNDERCROSSING
QA Service Level1 (Verified on 05/02/2018)

Sample Information

Sample Taken Date01/18/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/19/2019
Sample typeDepartment Acceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byDenis Last name of sampler or witnessed bySostrom
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCemex Redlands Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design number1555211
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedTT1
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-01-18-6
DIME Test ID: 2019-01-18-6-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2019-02-08

Test Results


Number of specimens: 1
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Ahmad Alzubi
Date of test: 01/29/2019
Identification number: 17RA
Width of specimen: 6.0625 inch
Depth of specimen: 6.0625 inch
Span length of specimen: 18 inch
Maximum load applied: 8650 lb
Curing history and apparent moisture condition of the specimen: satisfied
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: None
Age of specimen: 11 days
Age of specimen in hours: no data
Modulus of rupture: 735 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/1/2019