Summary for Test 2018-11-10-2-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212573
DEA: 010B5504
EFIS: 0112000137
DIST-CO-RTE-PM01-MEN-162-16.2
Award Date09/28/2017
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT ROADWAY, CONSTRUCT SOLDIER PILE AND TIEBACK WALL
Location DescriptionMENDOCINO COUNTY ON ROUTE 162 1 MILE EAST OF MIDDLE FORK EEL RIVER BRIDGE
QA Service Level1 (Verified on 10/03/2017)

Sample Information

Sample Taken Date11/10/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/28/2018
Sample typeQuality Assurance A brief description of the sampleCoupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byTom Last name of sampler or witnessed bySayver
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarSplice CMC Transportation Laboratory (TL) NumberC694524
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size6 Coupler ModelGriptwist
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A177056, 177527 Rebar Heat Number(s)PL17109115
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-11-10-2
DIME Test ID: 2018-11-10-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-12-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/29/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#6/19mm0.44047742108510Bar Broke, Ok NeckingBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke, Ok Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 11/30/2018