Summary for Test 2018-11-15-5-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212376
DEA: 044G8504
EFIS: 0413000052
DIST-CO-RTE-PM04-SM-1-R44.1
Award Date04/12/2018
Closeout Date09/01/2020
Work DescriptionREPLACE PEDESTRIAN OVERCROSSING
Location DescriptionSAN MATEO COUNTY IN PACIFICA AT THE SAN JOSE AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 05/23/2018)

Sample Information

Sample Taken Date11/15/2018 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2018
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAbbas Last name of sampler or witnessed byIranmanesh
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau, HRC Transportation Laboratory (TL) NumberC794241
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size9 Coupler Model500 510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)177275, A180128 Rebar Heat Number(s)65032488 02
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-11-15-5
DIME Test ID: 2018-11-15-5-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-11-23

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/16/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#9/29mm109932999329Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 11/16/2018