Summary for Test 2018-05-15-46-5
Test performed: AASHTO T283-14Project Information
Project Identifiers | Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 |
---|---|
DIST-CO-RTE-PM | 02-SIS-5-2.7/R11.4 |
Award Date | 03/12/2018 |
Closeout Date | 10/05/2020 |
Work Description | RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS |
Location Description | SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS |
QA Service Level | 1 (Verified on 04/04/2018) |
Sample Information
Sample Taken Date | 05/15/2018 | Sample Unique Key | 46 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/04/2018 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA eq. PG 64-28 M |
The quantity of what the sample constitutes | JMF Verification Renewal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Randy | Last name of sampler or witnessed by | Bibbens |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | D77680 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | J F Shea Construction Inc - Fawndale Rock and Asphalt - Redding CA | Transportation Laboratory (TL) Number | 898237 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF 18-03-R1 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Not set |
Sublot number | Not set | HMA Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-05-15-46
DIME Test ID: 2018-05-15-46-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2018-10-31
Test Results
Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 10/12/2018
Specimen Treatment: Treated
Average Dry Tensile Strength: 182 psi
Average Wet Tensile Strength: 180 psi
Tensile Strength Ratio: 99
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/31/2018 ✔