Summary for Test 2018-10-23-2-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211775
DEA: 024E6504
EFIS: 0212000012
DIST-CO-RTE-PM02-SIS-96-R52.5/88.4
Award Date07/10/2017
Closeout Date01/05/2021
Work DescriptionWIDEN BRIDGES,POLYESTER CONC OVERLAY,COLD PLANE AC PVMT,HMA,GUARDRAIL
Location DescriptionSISKIYOU COUNTY NEAR SEIAD VALLEY AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF THOMPSON CREEK BRIDGE TO 0.2 MILE EAST OF BEAVER CREEK BRIDGE
QA Service Level1 (Verified on 08/23/2017)

Sample Information

Sample Taken Date10/23/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/26/2018
Sample typeQuality Assurance A brief description of the sample7/8x2 1/4, 7/8x3 1/4, 7/8x3 1/2
The quantity of what the sample constitutes96, 46, 28 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9165170532
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCK Johnson Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-570-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)R390328A, R395568A, R400708A
Heat Number(s)100885409, 100885408, DL17102851 Nut Mfg. Lot Number(s)390328A, 395568A, 400708A
Washer Mfg. Lot Number(s) Bolt SpecificationA325
Bolt Length(s)2 1/4, 3 1/4, 3 1/2 Nut SpecificationA563 DH
Washer SpecificationF436 FinishHDG
Diameter/Size7/8x2 1/4, 7/8x3 1/4, 7/8x3 1/2 Bolt Mfg. Lot Number
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2018-10-23-2
DIME Test ID: 2018-10-23-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-11-06

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/29/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
13A400708A7/8\"65099289.610A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 10/30/2018