Summary for Test 2018-10-23-2-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 211775 DEA: 024E6504 EFIS: 0212000012 |
---|---|
DIST-CO-RTE-PM | 02-SIS-96-R52.5/88.4 |
Award Date | 07/10/2017 |
Closeout Date | 01/05/2021 |
Work Description | WIDEN BRIDGES,POLYESTER CONC OVERLAY,COLD PLANE AC PVMT,HMA,GUARDRAIL |
Location Description | SISKIYOU COUNTY NEAR SEIAD VALLEY AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF THOMPSON CREEK BRIDGE TO 0.2 MILE EAST OF BEAVER CREEK BRIDGE |
QA Service Level | 1 (Verified on 08/23/2017) |
Sample Information
Sample Taken Date | 10/23/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/26/2018 |
Sample type | Quality Assurance | A brief description of the sample | 7/8x2 1/4, 7/8x3 1/4, 7/8x3 1/2 |
The quantity of what the sample constitutes | 96, 46, 28 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CK Johnson | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-570-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | R390328A, R395568A, R400708A |
---|---|---|---|
Heat Number(s) | 100885409, 100885408, DL17102851 | Nut Mfg. Lot Number(s) | 390328A, 395568A, 400708A |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 2 1/4, 3 1/4, 3 1/2 | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8x2 1/4, 7/8x3 1/4, 7/8x3 1/2 | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2018-10-23-2
DIME Test ID: 2018-10-23-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-11-06
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/29/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2A | 395568A | 7/8\" | 66030 | 293.7 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 10/30/2018 ✔