Summary for Test 2018-10-04-1-1
Test performed: ASTM A722-15Project Information
Project Identifiers | Project ID: 213205 DEA: 051J6704 |
---|---|
DIST-CO-RTE-PM | 05-SB-192-15.4/15.6 |
Award Date | 02/20/2018 |
Closeout Date | 05/08/2019 |
Work Description | Replace bridge and restore roadway |
Location Description | Arroyo Paredon Bridge |
QA Service Level | 1 (Verified on 09/27/2018) |
Sample Information
Sample Taken Date | 10/04/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/05/2018 |
Sample type | Quality Assurance | A brief description of the sample | ATB A722 1-3/8 |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Carolina | Last name of sampler or witnessed by | Margarito |
Title of sampler | Asst METS Rep | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | WFE | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L73-020-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
Threaded Bar Type | Rebar Size | ||
Nut Specification for Threaded Bar | A29 | System Manufacturer | Not Available |
Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
Coating Standards | Uncoated | Bar Heat Number(s) | 62139760 |
Nut Heat Number(s) | 75071080 | Bar Lot Number | Unknown |
Nut Lot Number | Unknown | Coupler Heat Number(s) | Unknown |
Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2018-10-04-1
DIME Test ID: 2018-10-04-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-10-18
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/11/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 2 | A722 1.375\" Threaded Bar & Nut | L73-020-18 | 1.458 | 159121 | 131921 | 0 | 40.1 | A722 Threaded Bar and Nut | Brian |
General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/11/2018 ✔