Summary for Test 2018-10-08-2-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213248 DEA: 042K0104 EFIS: 0416000341 |
---|---|
DIST-CO-RTE-PM | 04-ALA-24,80,580,880,980-VAR |
Award Date | 05/17/2018 |
Closeout Date | 10/21/2019 |
Work Description | PATCH SPALLS AND REPAIR AC APPROACH. |
Location Description | ALAMEDA COUNTY AT VARIOUS LOCATION |
QA Service Level | 1 (Verified on 06/20/2018) |
Sample Information
Sample Taken Date | 10/08/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/08/2018 |
Sample type | Quality Assurance | A brief description of the sample | Bartec Couplers |
The quantity of what the sample constitutes | 150 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | TET | Telephone number of sampler | 707-310-2029 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-198-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | bartec | Intermediate Assembler or Fabricator | |
Rebar Size | 6 | Coupler Model | Bartec |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | DL12102191 | Rebar Heat Number(s) | SE1810180901 |
Rebar Size 2 | 6 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-10-08-2
DIME Test ID: 2018-10-08-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-10-17
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/10/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | C01 | #6/19mm | 0.44 | -0.0003 | 41586 | 94514 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/10/2018 ✔